Spark PLUS UV395™ anti-human MICA/MICB (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
6D4 (See other available formats)
Regulatory Status
RUO
Other Names
PERB11, MIC, MHC class I chain-related protein A, MICA, PERB11.1, MHC class I chain-related protein B, MICB, PERB11.2
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285670 50 µg 316€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

6D4 antibody reacts with a common epitope of the human nonclassical MHC class I chain-related protein A (MICA) and B (MICB), also known as PERB11.1 and PERB11.2. The MIC gene is located in MHC class I region. MICA/B are 65-75 kD stress-inducible glycoproteins with highly polymorphic. They are MHC class I-like transmembrane molecules that do not associate β2-microglobulin and do not present peptides. MICA and MICB share 85% identify, and are mainly expressed on Intestinal epithelial cells, epithelial tumor cells, endothelial cells, fibroblasts, and IFN-α-stimulated dendritic cells. MIC molecules bind NKG2D, an activating receptor, and induce activation of NK cells, and subset of CD8+ α/β T cells and γ/δ T cells, as well as suppression of T cell proliferation. MICA/B recognition is involved in the regulation of tumor surveillance, viral infection and autoimmune diseases. The 6D4 antibody is able to block MIC mediated cytotoxicity.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark PLUS UV395™ under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

* Spark PLUS UV395™ has a maximum excitation of 355 nm and a maximum emission of 385 nm.

Excitation Laser
Ultraviolet Laser (355 nm)
Application Notes

Additional reported (for the relevant formats) applications include: immunohistochemistry2,3,5 of acetone-fixed frozen sections and formalin-fixed paraffin-embedded tissue sections, immunoprecipitation7, and blocking2,3 of MIC mediated cytotoxicity. The Ultra-LEAF™ Purified antibody (Endotoxin < 0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for functional assays (Cat. Nos. 320919 & 320120).

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Groh V, et al. 1999. Science 279:1737.
  2. Groh V, et al. 1999. Proc. Natl. Acad. Sci. USA. 96:6879.
  3. Groh V, et al. 2001. Nature Immunol. 2:255.
  4. Li Z, et al. 2000. Immunogenetics 51:246.
  5. Park EJ, et al. 2003. J. Immunol. 171:4131.
  6. Jinushi M, et al. 2003. J. Immunol. 171:5423.
  7. Wu J, et al. 2003. J. Immunol. 170:4196.

Antigen Details

Structure
65-75 kD glycoprotein, MHC class I-like transmembrane molecules that do not associate ß2-microglobulin, highly polymorphic
Distribution

Intestinal epithelium, epithelial tumors, endothelial cells, fibroblasts, INF-a-stimulated dendritic cells

Function
Activation of NK cells, subset of CD8+ α/ß T cells and γ/δ T cells, suppression of T cell proliferation
Ligand/Receptor
NKG2D
Cell Type
Dendritic cells, Endothelial cells, Epithelial cells, Fibroblasts
Biology Area
Immunology, Innate Immunity
Molecular Family
MHC Antigens
Antigen References

1. Groh V, et al. 1996. Proc. Natl. Acad. Sci. USA. 93:12445.
2. Groh V, et al. 1999. Proc. Natl. Acad. Sci. USA. 96:6879.
3. Jinushi M, et al. 2003. J. Immunol. 170:1249.
4. Kriegeskorte AK, et al. 2005. Proc. Natl. Acad. Sci. USA. 102:11805.
5. Groh V, et al. 1999. Science 279:1737.

Gene ID
100507436 View all products for this Gene ID 4277 View all products for this Gene ID
UniProt
View information about MICA MICB on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

What if my requested antibody-dye combination doesn't perform as expected?

Flexi-Fluor™ products have been carefully selected by our scientists for their excellent conjugation properties and broad compatibility. In the rare case that an antibody-dye combination does not perform as expected due to the unique characteristics of a specific pairing, please contact our Technical Service team. We will work with you to identify alternative options to meet your panel requirements.

Go To Top Version: 1    Revision Date: 03.09.2026

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account