- Regulatory Status
- RUO
- Other Names
- Netosis, elastase
- Ave. Rating
- Submit a Review
- Product Citations
- publications
-
Human peripheral blood granulocytes were treated with PMA for two hours at 37°C. Cells were then stained using the NETosis Imaging and Flow Assay Kit and protocol and co-stained with anti-human CD16 (clone 3G8) PE and anti-human CD206 (clone 15-2) PE/Cyanine5. In the right plot, CD16+CD206+ N2 neutrophils are shown in purple and CD16+ CD206- N1 neutrophils are shown in blue. -
Human peripheral blood granulocytes were incubated with (purple) or without PMA (blue) for two hours at 37°C. Cells were then stained using the NETosis Imaging and Flow Assay Kit and anti-human CD16 (clone 3G8) PE. Data shown are gated on CD16-negative eosinophils.
| Cat # | Size | Price | Quantity Check Availability | Save | ||
|---|---|---|---|---|---|---|
| 421952 | 1 kit | 825 CHF | ||||
The NETosis Imaging and Flow Assay Kit is designed for the quantification and analysis of NETosis in both human and murine neutrophils by flow cytometry and live cell imaging.
NETosis is a specialized immune response in which neutrophils release neutrophil extracellular traps (NETs)–web-like chromatin structures coated with antimicrobial proteins and proteases such as neutrophil elastase—to capture and neutralize pathogens.
This kit combines a neutrophil elastase-activated fluorescent probe with two DNA-binding dyes: Hoechst 33342, which is membrane-permeable, and Helix Green, which is membrane-impermeable. These components facilitate the analysis of NETosis by detecting neutrophil elastase activity, extracellular DNA, and intact nuclei, offering a streamlined and rapid method for obtaining reliable results.
Kit Details
- Kit Contents
-
• Elastase Probe Far Red, 1 vial, lyophilized (Ex 675/Em 720, APC filter set)
• Hoechst 33342 solution, 1 vial, 150 µL (Ex 350/Em 461, DAPI filter set)
• Helix Green, 1 vial, 250 µL (Ex 495/Em 519, FITC filter set)
• PMA, 0.1mg/mL in DMSO, 1 vial, 200 µL
Product Details
- Verified Reactivity
- Human, Mouse
- Storage & Handling
- -20°C, protected from light
- Application
-
FC - Quality tested
Live cell imaging - Verified
In vivo imaging - Reported in the literature, not verified in house - Recommended Usage
-
Refer to product manual
-
Application References
(PubMed link indicates BioLegend citation) -
- Scales HE, et al. 2016. Rheumatology. 55(3):564-72.
- Kolaczkowska E, et al. 2015. Nat Commun. 6, 6673.
- Mitra S, et al. 2013. J Biomed Opt. 18(10):101314.
Antigen Details
- Cell Type
- Granulocytes, Neutrophils
- Biology Area
- Apoptosis/Tumor Suppressors/Cell Death, Cell Biology, Cell Death, Cell Motility/Cytoskeleton/Structure, Cell Structure, Immunology, Innate Immunity
- Molecular Family
- Enzymes and Regulators, Innate Immune Signaling, Nuclear Markers, Organelle Markers
- Gene ID
- NA
Login / Register 