- Clone
- CC2C6 (See other available formats)
- Regulatory Status
- RUO
- Other Names
- Rh-associated protein, gp42, integrin-associated protein, IAP, neurophilin
- Isotype
- Mouse IgG1, κ
- Ave. Rating
- Submit a Review
- Product Citations
- publications
CD47 also known as Rh-associated protein, gp42, integrin-associated protein (IAP), and neurophilin, is a 42-52 kD member of the immunoglobulin superfamily containing a five-pass transmembrane attachment. Two splice variants have been described in the cytoplasmic tail, the shorter form is expressed in bone-marrow-derived cells, endothelial cells, and fibroblasts while the longer form is expressed by neural tissues. CD47 expression is widely distributed in hematopoietic cells including thymocytes, T cells, B cells, monocytes, platelets, and erythrocytes as well as epithelial cells, endothelial cells, fibroblasts, and neural tissues. CD47 functions as an adhesion molecule and thrombospondin receptor and is non-covalently associated with β3 integrins CD51/CD61, CD41/CD61. Thrombospondin is a ligand for CD47; in the absence of CD47 mice show defects in host defense and β3 integrin-dependent ligand binding, migration, and cellular activation. CD47 is also part of the Rh complex on erythrocytes. The CC2C6 antibody recognizes human CD47 and has been shown to be useful for flow cytometry.
Product DetailsProduct Details
- Verified Reactivity
- Human
- Antibody Type
- Monoclonal
- Host Species
- Mouse
- Immunogen
- CCRF-CEM T-cell line
- Formulation
- Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
- Preparation
- The antibody was purified by affinity chromatography and conjugated with Spark PLUS B550™ under optimal conditions.
- Concentration
- 0.2 mg/mL
- Storage & Handling
- The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
- Application
-
FC
- Recommended Usage
-
Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.
For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.
* Spark PLUS B550™ has a maximum excitation of 516 nm and a maximum emission of 540 nm. - Excitation Laser
-
Blue Laser (488 nm)
- Application Notes
-
The CC2C6 monoclonal antibody can block the binding of HCD47 antibody to CD47.
Additional reported applications (for the relevant formats) include: blocking2 - Additional Product Notes
-
For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.
-
Application References
(PubMed link indicates BioLegend citation) -
- Seiffert M, et al. 1999. Blood 94:3633.
- Leclair P, et al. 2018. Cell Death Dis. 5:544 (Block)
Antigen Details
- Structure
- Member of the immunoglobulin superfamily, 42-52 kD protein with a five-pass transmembrane attachment. Two splice variants have been described in the cytoplasmic tail.
- Distribution
-
Wide distribution in hematopoietic cells including thymocytes, T cells, B cells, platelets, and erythrocytes as well as epithelial cells, endothelial cells, fibroblasts, and neural tissues.
- Function
- Adhesion molecule and thrombospondin receptor. In the absence of CD47, mice show defects in host defense and beta 3 integrin-dependent ligand binding, migration, and cellular activation. CD47 is a part of the Rh complex on erythrocytes.
- Ligand/Receptor
- Non-covalently associated with ß3 integrins CD51/CD61, CD41/CD61. Thrombospondin is a ligand for CD47.
- Cell Type
- B cells, Endothelial cells, Epithelial cells, Erythrocytes, Fibroblasts, Platelets, T cells, Thymocytes
- Biology Area
- Immunology
- Molecular Family
- CD Molecules
- Antigen References
-
1. Anstee DJ, et al. 1995. In Leucocyte Typing V (Schlossman ed.) Oxford University Press Oxford pp233-234.
2. Brown E, et al. 1990. J. Cell Biol. 111:2785.
3. Gao AG, et al. 1996. J. Biol. Chem. 271:21.
4. Lindberg FP, et al. 1994. J. Biol. Chem. 269:1567. - Gene ID
- 961 View all products for this Gene ID
- UniProt
- View information about CD47 on UniProt.org
Related FAQs
- What are Flexi-Fluors?
-
Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer.
- How quickly will I receive my order?
-
We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary.
- How are Flexi-Fluors different from regular catalog products?
-
Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.
- How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?
-
Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL.
For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.
- I can’t find the antibody-dye combination that I need. When will it be available?
-
We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services.
- I need help to validate the performance of my Flexi-Fluor. Who should I contact?
-
Please get in touch with Technical Service for assistance.
- Can I order more than 50 μg of a Flexi-Fluor?
-
Yes, you can order multiple vials of the same Flexi-Fluor products. We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.
- What is the expiration date of my Flexi-Fluor?
-
Expiration dates can be found on the vial label or by using our CoA lookup tool.
- What if my requested antibody-dye combination doesn't perform as expected?
-
Flexi-Fluor™ products have been carefully selected by our scientists for their excellent conjugation properties and broad compatibility. In the rare case that an antibody-dye combination does not perform as expected due to the unique characteristics of a specific pairing, please contact our Technical Service team. We will work with you to identify alternative options to meet your panel requirements.
Other Formats
View All CD47 Reagents Request Custom Conjugation| Description | Clone | Applications |
|---|---|---|
| PE/Cyanine7 anti-human CD47 | CC2C6 | FC |
| Pacific Blue™ anti-human CD47 | CC2C6 | FC |
| APC/Fire™ 750 anti-human CD47 | CC2C6 | FC |
| Alexa Fluor® 647 anti-human CD47 | CC2C6 | FC |
| Alexa Fluor® 700 anti-human CD47 | CC2C6 | FC |
| APC anti-human CD47 | CC2C6 | FC |
| Brilliant Violet 421™ anti-human CD47 | CC2C6 | FC |
| Brilliant Violet 605™ anti-human CD47 | CC2C6 | FC |
| TotalSeq™-A0026 anti-human CD47 | CC2C6 | PG |
| TotalSeq™-C0026 anti-human CD47 | CC2C6 | PG |
| Purified anti-human CD47 | CC2C6 | FC,ICC |
| Biotin anti-human CD47 | CC2C6 | FC |
| FITC anti-human CD47 | CC2C6 | FC |
| PE anti-human CD47 | CC2C6 | FC |
| PerCP/Cyanine5.5 anti-human CD47 | CC2C6 | FC |
| PE/Dazzle™ 594 anti-human CD47 Antibody | CC2C6 | FC |
| TotalSeq™-B0026 anti-human CD47 Antibody | CC2C6 | PG |
| TotalSeq™-D0026 anti-human CD47 | CC2C6 | PG |
| Spark PLUS UV395™ anti-human CD47 | CC2C6 | FC |
| Spark PLUS B550™ anti-human CD47 (Flexi-Fluor™) | CC2C6 | FC |
Compare Data Across All Formats
This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.
-
PE/Cyanine7 anti-human CD47
Human peripheral blood monocytes were stained with CD47 (clo... -
Pacific Blue™ anti-human CD47
Human peripheral blood lymphocytes were stained with CD47 (c... -
APC/Fire™ 750 anti-human CD47
Human peripheral blood monocytes were stained with CD47 (clo... -
Alexa Fluor® 647 anti-human CD47
Human peripheral blood monocytes were stained with CD47 (clo... -
Alexa Fluor® 700 anti-human CD47
Human peripheral blood lymphocytes were stained with CD47 (c... -
APC anti-human CD47
Human peripheral blood lymphocytes were stained with CD47 (c... -
Brilliant Violet 421™ anti-human CD47
Human peripheral blood monocytes were stained with CD47 (cl... -
Brilliant Violet 605™ anti-human CD47
Human peripheral blood monocytes were stained with CD47 (clo... -
TotalSeq™-A0026 anti-human CD47
-
TotalSeq™-C0026 anti-human CD47
-
Purified anti-human CD47
Human peripheral blood lymphocytes stained with purified CC2...
MCF-7 breast cancer cell line was stained with anti-human CD... -
Biotin anti-human CD47
Human peripheral blood lymphocytes stained with biotinylated... -
FITC anti-human CD47
Human peripheral blood lymphocytes stained with CC2C6 FITC -
PE anti-human CD47
Human peripheral blood lymphocytes stained with CC2C6 PE -
PerCP/Cyanine5.5 anti-human CD47
Human peripheral blood lymphocytes were stained with CD47 (c... -
PE/Dazzle™ 594 anti-human CD47 Antibody
Human peripheral blood lymphocytes were stained with anti-hu... -
TotalSeq™-B0026 anti-human CD47 Antibody
-
TotalSeq™-D0026 anti-human CD47
-
Spark PLUS UV395™ anti-human CD47
Human peripheral blood monocytes were stained with anti-huma... -
Spark PLUS B550™ anti-human CD47 (Flexi-Fluor™)
Login / Register 



Follow Us