Spark PLUS UV395™ anti-human CD70 (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
113-16 (See other available formats)
Regulatory Status
RUO
Other Names
CD27 ligand, CD27L, Ki-24 antigen, Tumor necrosis factor ligand superfamily, member 7 (TNFSF7)
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285653 50 µg 395 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD70, also known as CD27L, is a 50 kD type II transmembrane glycoprotein and member of the tumor necrosis factor superfamily. CD70 is expressed on activated T, B and NK cells, activated plasmacytoid dendritic cells (pDCs), and chronic B cell lymphocytic leukemia and large B cell lymphomas. CD70 costimulates T cell proliferation and differentiation. It plays a role in the pDC-induced B cell differentiation. The ligand of CD70 is CD27.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
CD70-transfected L cells
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark PLUS UV395™ under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

* Spark PLUS UV395™ has a maximum excitation of 355 nm and a maximum emission of 385 nm.

Excitation Laser
Ultraviolet Laser (355 nm)
Application Notes

Additional reported applications for the relevant formats include: blocking of plasmacytoid dendritic cell induced B cell proliferation and Ig secretion1.

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Shaw J, et al. 2010. Blood 115:3051. (Block)

Antigen Details

Structure
Type II transmembrane glycoprotein, member of the tumor necrosis factor superfamily, 50 kD
Distribution

Activated T cells and B cells, activated NK cells, activated plasmacytoid dendritic cells, some B cell lymphomas

Function
Role in T cell proliferation, generation of cytolytic and memory T cells, B cell proliferation and differentiation
Ligand/Receptor
CD27
Cell Type
B cells, Dendritic cells, NK cells, T cells
Biology Area
Costimulatory Molecules, Immunology
Molecular Family
CD Molecules
Antigen References

1. Bowman MR, et al. 1994. J. Immunol. 152:1756.
2. Shaw J, et al. 2010. Blood 115:3051.
3. Keller AM, et al. 2009. Blood 113:5167.

Gene ID
970 View all products for this Gene ID
UniProt
View information about CD70 on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

What if my requested antibody-dye combination doesn't perform as expected?

Flexi-Fluor™ products have been carefully selected by our scientists for their excellent conjugation properties and broad compatibility. In the rare case that an antibody-dye combination does not perform as expected due to the unique characteristics of a specific pairing, please contact our Technical Service team. We will work with you to identify alternative options to meet your panel requirements.

Go To Top Version: 1    Revision Date: 03.06.2026

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account