Spark PLUS B550™ anti-mouse CD184 (CXCR4) (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
L276F12 (See other available formats)
Regulatory Status
RUO
Other Names
Fusin, LESTR, Sdf1r, Cmkar4, PB-CKR, PBSF/SDF-1
Isotype
Rat IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Check Availability Save
285635 50 µg 277€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD184, also known as CXCR4, is a member of the G protein coupled receptor family that binds CXCL12 (SDF1). CXCR4 and CXCL12 play an important role in immune and inflammatory responses through the regulation of cell migration and growth. CXCR4 plays a crucial role in the pathogenesis of several autoimmune diseases such as atherosclerosis, rheumatoid arthritis, and wound healing. In addition, CXCR4 is the cofactor for fusion and entry of the T cell-tropic form of HIV-1.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Mouse CXCR4-transfected cells
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark PLUS B550™ under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

* Spark PLUS B550™ has a maximum excitation of 516 nm and a maximum emission of 540 nm.

Excitation Laser
Blue Laser (488 nm)
Application Notes

Additional reported applications (for the relevant formats) include: in vivo blocking1

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Costa MJ, et al. 2018. PLoS One. 13:e0194688 (Block) PubMed

Antigen Details

Structure
G-protein-coupled seven transmembrane receptor, 39.7 kD
Distribution

T lymphocytes, monocytes, macrophages, tissue-committed stem/progenitor cells (TCSCs), mast cells, vascular smooth muscle cells (VSMCs)

Function
Development of cardiovascular and central nervous system, hematopoiesis, and colonization of BM by fetal liver-derived hematopoietic stem cells (HSCs) during embryogenesis, homing and egress of CD34+ CXCR4+ progenitor cells from bone marrow, and their migration into peripheral tissues. Critical role in homing of cancer cells to specific metastatic sites. Possible role in the ubiquitin proteosome system.
Interaction
Robo -1
Ligand/Receptor
CXCL12 (SDF-1)
Cell Type
Macrophages, Mast cells, Mesenchymal Stem Cells, Monocytes, Neural Stem Cells, T cells
Biology Area
Angiogenesis, Cell Biology, Cell Motility/Cytoskeleton/Structure, Immunology, Neuroscience, Neuroscience Cell Markers, Signal Transduction, Stem Cells, Ubiquitin/Protein Degradation
Molecular Family
CD Molecules, Cytokine/Chemokine Receptors, GPCR
Antigen References

1. Kucia M, et al. 2005. Stem Cells 23:879.
2. Muller A, et al. 2001. Nature 410:50.
3. Saini V, et al. 2010. J. Biol. Chem. 285:15566.
4. Prasad A, et al. 2007. J. Leuko. Biol. 82:465. 
5. De Klerck B, et al. 2005. Arthritis Res. Ther. 7:R1208.
6. Rueda P, et al. 2008. PLoS One 3:e2543. 
7. Feng Y, et al. 1996. Science 272:872.

Gene ID
12767 View all products for this Gene ID
UniProt
View information about CD184 on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

What if my requested antibody-dye combination doesn't perform as expected?

Flexi-Fluor™ products have been carefully selected by our scientists for their excellent conjugation properties and broad compatibility. In the rare case that an antibody-dye combination does not perform as expected due to the unique characteristics of a specific pairing, please contact our Technical Service team. We will work with you to identify alternative options to meet your panel requirements.

Go To Top Version: 1    Revision Date: 03/04/2026

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account