StarBright UltraViolet 740 anti-mouse CD11b Basic Panel

Pricing & Availability
Clone
M1/70; 145-2C11;
Regulatory Status
RUO
Ave. Rating
Submit a Review
Product Citations
publications
M1-70_SBUV740_CD11b_FC_071425
C57BL/6 mouse bone marrow cells were stained with anti-mouse Ly-6G/Ly-6C (Gr-1) (clone RA3-6B2) FITC and anti-mouse/human CD11b (clone M1/70) StarBright UltraViolet 740 (left) or stained with anti-mouse Ly-6G/Ly-6C (Gr-1) (clone RA3-6B2) FITC only (right).
  • M1-70_SBUV740_CD11b_FC_071425
    C57BL/6 mouse bone marrow cells were stained with anti-mouse Ly-6G/Ly-6C (Gr-1) (clone RA3-6B2) FITC and anti-mouse/human CD11b (clone M1/70) StarBright UltraViolet 740 (left) or stained with anti-mouse Ly-6G/Ly-6C (Gr-1) (clone RA3-6B2) FITC only (right).
Cat # Size Price Quantity Check Availability Save
391033 1 kit 240€
 
Check Availability


Need larger quantities of this item?
Request Bulk Quote

This item is temporarily unavailable.

 

The StarBright component of this kit is also available for purchase as part of a multicolor flow cytometry panel: StarBright UltraViolet 740 anti-mouse/human CD11b (clone M1/70), 150 µg (Cat. No. 101253). To request a sample, contact your local Field representative.

Description

StarBright Basic Panels offer a core set of conjugated antibodies for multicolor analysis. These panels can be used independently for preliminary testing and basic characterization, or can serve as a backbone for a larger multiplex panel.

This StarBright Basic Panel contains 3 components:

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse, Human
Concentration
The StarBright mass size conjugates are bottled at 0.6mg/mL (the concentration relates to the dye component of the conjugate). Additional component concentrations are variable. To obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.
Storage & Handling
Antibody solutions should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.

7-AAD should be stored between 2°C and 8°C and protected from light.
Application

FC - Quality tested by component

Recommended Usage

Each lot of the antibodies in this kit is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 2.0 µg per million cells in 100 µL staining volume. It is recommended that the reagent be titrated for optimal performance for each application.

* StarBright UltraViolet 740 has a maximum excitation of 343 nm and a maximum emission of 737 nm.


StarBright dyes are powered by Bio-Rad®. STARBRIGHT is a trademark of Bio-Rad Laboratories, Inc.

Related FAQs

What is a “StarBright panel”?

A StarBright panel is a multiplex panel that includes at least one StarBright conjugate.

Will my StarBright panel be provided as a cocktail?

StarBright products purchased as part of a panel or StarBright Basic Panel will be provided in individual vials. To order premade cocktails, please contact our Custom Solutions Team.

Are StarBright GMP/ASR products available?

StarBright ASR and GMP products are coming soon.

Are StarBright custom products available?

Yes, please contact our Custom Solutions Team.

Will StarBright isotype controls be offered?

We are not planning to offer StarBright isotype controls at this time. Fluorescence Minus One (FMO) controls should be used to define gating boundaries.

What amount of a StarBright conjugate should I use?

Antibody conjugates should be titrated for optimal performance in each application. To directly compare performance with a traditional or polymer-conjugated antibody, we recommend using the same volume of each product for analysis. Due to differences in the quantification of product mass, StarBright Dyes are prepared in equivalent volumes.

Why shouldn’t I compare the mass (μg) of a StarBright conjugate to a traditional or polymer conjugate?

For StarBright conjugates, the reported mass refers to the mass of the dye component. For traditional conjugates, the reported mass refers to the mass of the antibody component. This is because traditional conjugates have multiple dye molecules attached to one antibody, while StarBright conjugates have multiple antibodies attached to a single StarBright Dye.

Go To Top Version: 2    Revision Date: 08/13/2025

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account